Mitsubishi
Heavy Industries Air Heat Pump Model:
FDCW100VNX (3.5~12.0)
kW
|
|
Mitsubishi
Heavy Industries Air to Water Heat Pump is a complete modern
system for heating, cooling and producing hot sanitary water
for small houses, offering effective energy saving and
reducing carbon dioxide emission. Our product is safe and
economical with integrated hot water heater, immersion
heater, circulating pump and climate system within the
indoor unit.
The
heat energy is retrieved from the outdoor air through an
outdoor unit (FDCW100VNX), and is transferred to the indoor
unit (HM270V) by the medium of refrigerant circulated in
closed piping system. This eliminates the needs of bore
holes and coils in the ground for conventional systems.
Optimum
annual operation costs thanks to the inverter driven
compressor. The speed of the compressor is controlled
according to the demand, and the industry’s highest COP
level of 3.70 in heating operation has been achieved.
The
compact size (600x650mm footprint) has been achieved by
integrating the hot water tank for sanitary water together
with the water heat exchanger in the indoor unit.
Electric wiring and piping works are simpler due to
integrated indoor unit design.
Max
temperature flow line is 65°C with use of a large-capacity
auxiliary electric heater as standard equipment for back-up,
so that the system will be able to cope with irregular and
excessive use of hot water. (58°C with only use of
compressor). Various sterilization temperature settings are
available according to the requirements of each country.
Key
Product Feature's:
Model:
FDCW100VNX
Nominal
Heating - 9.0 (3.5~12.0) kW
Nominal
Cooling - 8.0
(3.0~9.0) kW
COP
Heating - 3.75
240Volt
1 phase (also available in 3phase)
Refrigerant
R417A / R410A
Rated to
-20DegC Heating
Heating and
cooling
Dimensions:
L1760, W600, D650
Weight
214Kg ( indoor and outdoor)
Heating
|
|
Nominal
Capacity (min~max) |
9.0 (3.5~12.0) kW |
COP
(Nominal) |
3.70 |
Tapping
Capacity (Sanitary hot water) in:15°C |
out:40°C |
270
liter 12 liter/min
200
liter 16 liter/min |
Tapping
Capacity (Sanitary hot water) in:15°C |
out:40°C |
Cooling |
|
Nominal
Capacity (min~max) |
8.0
(3.0~9.0) |
COP
(Nominal) |
2.87 |
Technical
Data |
|
Working
range during heating with compressor (ambient
temperature) |
-20 - +43°C |
Working
range during cooling (ambient temperature) |
|
+15
- +43°C |
Max
temperature flow line |
65°C |
Max
temperature flow line, only use of compressor |
|
58°C |
Refrigerant
quantity (R410A) |
2.9 kg |
Max
length, refrigerant pipe |
|
12
m |
Max
height difference, refrigerant pipe
|
7 m
|
Dimensions,
refrigerant pipe
|
|
Gas
pipe : OD15.88 (5/8")
Liquid
pipe : OD9.52 (3/8") |
Pipe
connections (outdoor to indoor) |
|
Flare |
HM270V
(Indoor unit) |
|
Immersion
heater |
Max
9 kW |
Volume,
total |
|
270
litre |
5%+
- |
Volume,
hot water coil |
14
litre |
Height
|
|
1760
mm
(+20-50
mm, adjustable feet) |
Width |
600 mm |
Depth |
|
650
mm |
Weight
(without water in tank) |
140
kg |
Electrical
connections |
|
1Phase
230V / 3Phase 400V 50Hz |
FDCW100VNX
(Outdoor unit) |
|
Height |
845 mm |
Width |
|
970
mm |
Depth |
370
mm (+80 mm with foot rail) |
Weight |
|
74
kg |
|