High Output Commercial/industrial Air Source Heat-pump Fortismore CFM125 (72 Kw / 240000 Btu)

 

The CFM125 is a high powered commercial/industrial air source heat-pump boiler with 72 kW / 240000 Btu output. The CFM125 air source heat-pump is effectively a direct replacement for fossil fuel boilers with CO2 levels being vastly reduced. The output temperature can reach up to 65 but the unit has a internal electric heater which raises the temperature to 75 DegC periodically. These systems have seen service within many commercial buildings such as hotels, factories and offices but notably the California Rain Forest Spa which installed 10 x CFM125 systems for the swimming and spa areas. These units can also produce chilled water, all that would be required is a separate chilled water tank (as in picture below).

The latest UK models from all the major manufactures. Air source heat pumps are a easy way of replacing a existing fossil fuel heating system. Off the gas grid locations are particularly expensive to run especially when oil is used and there is always a issue of a big oil tank which needs to be sited on the property which can be unsightly. Air source heat pumps have a outdoor condensing unit (heat collector) which collects the heat from the ambient air. These can be fixed on a wall or level and generally look exactly the same as a air conditioning system outdoor condensing unit.

 

 

MODEL

CFM 103

CFM 105

CFM 110

CFM 115

 

CFM 120

CFM 125

HEATING CAPACITY

9.77

15.8

32.4

52

60

72

DESIGNED WATER OUTPUT TEMP

55

55

55

55

55

55

HIGHEST WATER OUTPUT TEMP

65

65

65

65

65

65

POWER CONSUMPTION(KW)

2.4

3.9

8.1

13

15

18

STARTING AMPERE(A)

45

28

66.5

99.75

133.25

166.3

RUNNING AMPERE(A)

11.2

7.1

13.3

19.95

26.65

33.26

POWER SUPPLY

220V~50Hz

380V 3PH~ 50Hz

380V 3PH~ 50Hz

380V 3PH~ 50Hz

380V 3PH~ 50Hz

380V 3PH~ 50Hz

WORKING TEMP

-12 to 43

-12 to 43

-12 to 43

-12 to 43

-12 to 43

 -12 to 43

DIMENSION

710×710×830

810x810x1365

1450×705×1475

1650×800×1450

2015×970×2025

2015×970×2025

REGRIGRANT

407C  1.8kg

407C 2.6kg

407C 5.2kg

407C  7.8kg

407C 10.8kg

407C  13.5kg

 

  Products:

 

LG Therma V Air Heat Pump Model: AHUW126A0 + H12SNE 12 kW

LG Therma V Air Heat Pump Model: AHUW126A0 + H12SNE 12 kW

LG Therma V Air Heat Pump Model: AHUW126A0 + H12SNE 12 kW

LG Therma V Air Heat Pump Model: AHUW146A0 + H14SNE 14 kW

LG Therma V Air Heat Pump Model: AHUW126A0 + H12SNE 12 kW

LG Therma V Air Heat Pump Model: AHUW166A0 + H16SNE 16 kW

Hitachi AquaFree RWM 4.0FSN1E heat-pump boiler (14.6 kW / 50000 Btu)

Hitachi AquaFree RWM 4.0FSN1E heat-pump boiler (14.6 kW / 50000 Btu)

Hitachi AquaFree RWM 4.0FSN1E heat-pump boiler (14.6 kW / 50000 Btu)

Hitachi AquaFree RWM 5.0FSN1E heat-pump boiler (16.7 kW / 57000 Btu)

Mitsubishi Heavy Industries Air To Water Heat Pump Model: FDCW100VNX (3.5 - 12.0) kW

Mitsubishi Heavy Industries Air To Water Heat Pump Model: FDCW100VNX (3.5 - 12.0) kW

 

Panasonic Aquarea Air to Water Heat Pump Monobloc Systems

Panasonic Aquarea Air to Water Heat Pump Monobloc Systems

 

Daikin Altherma Heating Only Air Source Heat-Pump Boiler System installation kit

Daikin Altherma Heating Only Air Source Heat-Pump Boiler System installation kit

Hitachi RHUE-3AVHN Yutaki "all in one" air source heat-pump boiler (8.2 kW / 28000 Btu) DHW/heating

Hitachi RHUE-3AVHN Yutaki "all in one" air source heat-pump boiler (8.2 kW / 28000 Btu) DHW/heating

 

 

Air to Water Basics:



The outdoor air source condensing unit comprises of a refrigeration compressor, a condensing coil (Ambient air exchanger), fan and water heat exchanger where collected heat from the ambient air is transferred to the water. Most air source heat pumps run on R410a refrigerant gas which has a maximum heat to water transfer temperature of around 60 DegC. Other machines run on R417a which is a replacement for R22 which is now not in use (as from 2010). R417a machines maximum heat to water transfer temperature is 55 DegC, both Gases require a booster electric heater to take the water temperature above 65 DegC to surpass the legionnaires breeding temperature. There is one machine which uses R410a and reaches 65 DegC, this is the Daikin Altherma Heating Only Air Source Heat-Pump Boiler System high temperature unit. This system can be very expensive. Other options are the Sanyo CO2 system which reaches 80 DegC comes as a complete system but uses the heat store principle where a water tank which has multiple coils is used as a central store of heat.

Related News:

Trianco Activair Air Source Heat-pump S500 (5 KW / 18000 Btu) for DHW (basic non-inverter type which requires a heat store water tank to transfer heat to) (No Longer Available, Trianco went bust 2010)

 

Email Us


 

Contact Us:

Sales Installation and Service UK: +44 (0)1234 841221
Tel UK: 01234 841221        
Fax: +44 (0)1234 852662

Address:

Orion Air Conditioning And Refrigeration Limited
10 Grisedale Court
Woburn Road Industrial Estate
Kempston
Bedfordshire
MK42 7EE
United Kingdom

Email:  
[email protected]

 

Shop For Our Products On-line

 

 

 

 

 

 

 

 

 

Orion Air Conditioning & Refrigeration Ltd, 10 Grisedale Court, Woburn Road Industrial Estate, Kempston, Bedfordshire, MK42 7EE, UK

Terms of Use | Privacy Statement | Accessibility |    home   |   sitemap

Orion Air conditioning and refrigeration ltd. All rights reserved

     Last updated - 24/04/2020